ATR chassis is liquid cool

On Elma-Mektron’s Stand 1767 is a functioning demonstration of its new dual-wall, liquid-cooled air transport rack (ATR) chassis, developed from ATR chassis is liquid cool official online show daily 32 dsei.janes.com its field-proven air-cooled design, which is in service on numerous fighting platforms.

The liquid-cooled version offers a 300% increase in thermal efficiency, providing a thermal budget of up to 1,500W per chassis, enabling the latest high-performance boards to run well within their operating temperature envelope. The dual-wall modular design significantly reduces mean time to repair.

The cooling sidewalls are line-replaceable units, so a swap-out is a simple process that can be carried out in the field. As the two sides are independent, cooling is still provided in the event of damage to one side; the design also gives additional protection to the vulnerable rear face of the chassis.

Three versions using different materials, protective coatings and connectors are available, enabling sea water, aviation fuel or CFCs, ammonia or various alcohols to be used as the cooling fluid. The patented High Integrity Frame design is typically 25% lighter than conventional dip-brazed constructions.

 